How to reprogram the IR Sensor Button with Remote Control Nov 04, 2020

1.Product introduction

This product is EB-16R and EB-17R series Infrared Remote Access Controller. 

The product design has many functions such as distance sensing, delay, remote unlocking(inching, self-locking, learning and clearing), and can be selected by itself. 


2. Product Picture


3. Technical parameters

Operating voltage: DC12V

Standby current:≤50mA. 

433 Remote control distance of remote controller:> 15 m

Storage capacity:30 users

Unlock delay time: 0 ≤ 30 seconds adjustable

Sensing distance:5~20cm. 

Overall dimension:86-86-26mm


4. Functional Operation

Note: after the power is turned on, the blue light is always on and the machine is in standby state.

(1)433 remote control function:


-->Short circuit cap  -->A position where a short circuit cap can be plugged in. 

S--learning:the short circuit cap is inserted into the S position of the double-way output pin mark point, and the blue light flashes and the machine is in learning state;Pressing the 433 remote control(buzzer rings)indicates that the learning information is successfully entered. 


Note: the remote controller can input 30 users, if you want to enter the 31st user, the 31st user's information will be transferred to the first user, the first user's data will be invalid, and so on. 


N--crawl :After the short circuit cap is inserted into the N position of the double output needle punctuation point, the blue light is always on. Press the remote controller button (green light, buzzer call) to unlock and reset automatically after 0.5s._x000d_ Note: in click mode, single key, double key remote control can be locked by any key, self-reset after 0.5s. -Self-locking: After the short-circuit cap is inserted in the L position of the two-way output pin point, press the remote control A key(The buzzer sounds, the green light is on, it is always in the unlocked state)-->Press the B key of the remote control again, the buzzer rings, and the blue light is on and reset. Press the B key of the remote control again, the buzzer rings, and the blue light is on and reset


Note: In the self-locking mode, the single key remote control can only be unlocked and cannot be locked; the double bond remote control A key is unlocked, and the B key is reset.

D--Delete.: the short-circuit cap is inserted in the D position of the two-way output pin-and-pin punctuation, the blue light flashes, and the long-time sound is long after the five-sound, and the long-ringing state indicates that the remote controller data is deleted successfully.


(2)Distance adjustment.

-->potential device

The induction distance can be adjusted by twisting the blue square potentiometer behind the circuit board, the range of which can be adjusted is 5 × 20 cm, the clockwise twisting is small, and the counterclockwise twisting is large.


5. Wiring Diagram